User`s guide
Monitoring and Managing the DL3100 5-9
5
Monitoring HSDB and HVDB Alarms and Status
You use the Current HSDB Alarms & Status Items Menu and the Current
HVDB Alarms & Status Items Menu to view HSDB and HVDB alarm and
status items.
To access these screens, you must Þrst select the HSDB or HVDB device
from any main menu. Then, from the HSDB or HVDB Main Menu, select
Alarms & Status and press Return. Examples of both Alarms & Status
menus are shown in Figure 5-5 and Figure 5-6.
RAM Test Failed Minor The RAM test failed during DL3100
initialization.
ROM Checksum Failed Minor The ROM checksum failed during DL3100
initialization.
Processor Restart Status The DL3100 unit has been reset.
External Alarm Input Active Status External alarm input relay is active.
Excessive Temperature Minor The temperature sensor indicates the
DL3100 chassis is “too hot.” This could be
caused by a failure of the cooling fan,
blockage of cooling vents, or poor site
selection when the unit was installed. The
unit is designed to operate at <
50°C.
NOTE: These are view-only screens; you cannot make changes to
them.
Table 5-1 T3MB Alarms and Status Conditions (Continued)
Message Severity Description