User`s guide
Configuring the DL3100 4-25
4
Configuring the HVDB
You use the HVDB ConÞguration and Connections Menu to conÞgure the
HVDB.
To access the HVDB ConÞguration and Connections Menu, select the
HVDB device from any main menu. Next select ConÞguration &
Connections from the HVDB Main Menu and press Return.
Figure 4-12 shows an example of the HVDB ConÞguration and
Connections Menu.
Figure 4-12 HVDB Configuration and Connections Menu
The HVDB conÞgurable parameters are the same as those of the HSDB
with the exceptions of CTS Control and TD Clock. These parameters are
deÞned as follows:
HVDB Configuration and Connections Menu Parameters
The HVDB ConÞguration and Connections Menu parameters are as
follows:
¥ CTS ControlÑAssert CTS or Auto CTS (DefaultÑAssert CTS)
Assert CTSÑWhen this feature is enabled the CTS (clear to send) signal
is always sent to the DTE regardless of the status of the RTS signal.
Auto CTSÑSelect this mode to activate CTS when RTS is active and
either a loop is in progress or the DTE is connected to the T3.