User`s guide
2-2 DL3100 User’s Guide—November 1998
2
From one to three DTE boardsÑTwo types of DTE boards are supported: a
high-speed DTE Board (HSDB) and a V.35 DTE Board (HVDB). Each of
these interface modules has one DTE port.
A front panelÑThe front panel consists of a 16-character vacuum
ßuorescent display, a 4-key keypad, and various LEDs. This panel can be
used to provision the unit, run diagnostic tests, or gain access to
performance statistics.
A built-in power supplyÑThe power supply has a range of 120 VAC to 240
VAC or -48 VDC. The DL3100 must be ordered as an AC or DC powered
unit.
DL3100 Features
The DL3100 offers the following features:
¥ Easy local installation and conÞguration using an ANSI (VT100ª)
compatible terminal
¥ Remote control through a Hayes-compatible modem or serial link
¥ Point-to-point connectivity
¥ Standard DS-3 and C-bit Parity framing format
¥ User-selectable bandwidth in increments from 300 kbps up to 44.2 Mbps
¥ Front panel LEDs and test jacks
¥ HSSI or V.35 electrical interface to the DTE on industry standard
connectors
¥ Provides a self-sychronizing scrambler option that scrambles data
before sending it to the network
¥ Provides local or remote control via an SNMP Management System,
ASCII terminal or network management system.
¥ Allows daisy-chaining of co-located units
¥ Alarm reporting capability
¥ Downloadable code
¥ SNMP MIB II support. In addition to supporting RFC 1157, 1213 and
1407, a device-speciÞc enterprise MIB is also available
¥ FEAC code support per T1.107a