6. Set the T3 (DS3) Transmit Clock: Network or Internal.
If the carrier is providing timing on the T3 (DS3) select Network
timing. If there is no timing on the circuit, set one DL3100 to Internal
and the remote to Network timing. If you are unsure, assume there
is no circuit timing and select Net timing.
7. Select ConÞrm to set the parameter you changed.
8. Select Exit to return to the Node/T3MB Main Menu.
DTE Port Configuration
From the Node/T3MB Main Menu select Select Device. Type the number n
(the DTE port connected to your DTE device) and press Enter. This action
will take you to the HSDB/HVDB Main Menu for DTE port n. The DL3100
can support up to 3 DTE ports; therefore, n = 0-3. If you are unsure, type
the number 1 and press Enter for DTE port 1.
Figure 1-4 HSDB Main Menu
Then select the ConÞguration & Connections submenu.