User`s guide

DL3100 Quick Configuration 1-5
1
Figure 1-3 T3MB Configuration
Configuration Actions
1. Set the Device Name, up to 20 characters.
2. Set the Scrambler option. When Enabled, this option allows for
the DL3100 to ÒscrambleÓ user data to prevent errors on pattern
sensitive Þber equipment along the DS3 transmission path. Both
the local and remote DL3100s must be set the same. If you are
unsure, set both units for Scrambler Enabled.
3. Set the T3 (DS3) Framing Format which the carrier recommends:
C-bit or M13. If you are unsure, select C-Bit Parity. Both the
local and remote DL3100Õs must be set the same.
4. Set the Line Build Out (LBO): > or < 225 feet. LBO selects the
distance between the DL3100 T3 (DS3) interface and the carrier
demarcation point.
5. Set the Applications Data Link coding: NRZ or NRZI.
Applications Data Link sets the T3 Data Link coding. Both the
local and remote DL3100Õs must be set the same. If you are unsure,
set both to NRZI.