User`s guide

A-10 DL3100 User’s Guide—November 1998
A
T3MB Alarm Thresholds Major Minor
Bipolar Violations 1 x 10 -4 1 x 10 -6
P-bit Parity Errors 1 x 10 -4 1 x 10 -6
CP-bit Parity Errors 1 x 10 -4 1 x 10 -6
Frame Bit Errors 1 x 10 -4 1 x 10 -6
Data Port Configuration - HSDB Data Port Configuration - HVDB
Module Service In Service CTS Control Assert
Hardware Rev. (read-only) SCTE Normal
Module Name Not assigned
Data Rate 300 kbps-44.2 Mbps
Clock Mode Normal
SNMP Configuration
Node IP Address 0.0.0.0 Node IP Subnet Mask 0.0.0.0
Trap IP Address 0.0.0.0 Read Community String Public
Write Community String Public Trap Community String Public
SNMP Baud Rate 9600 SNMP #Bits and Parity 8 bits No Parity
SNMP Stop Bits 2 bits
Comm Port and Terminal Configuration
Multidrop Enabled
Comm Port
9600, 8, no parity, 2 stop bits
Comm Port XON/XOFF
Enabled