Operating instructions
12 | MCO-5211
5 Technical Specifications
BNC Channels (Basic and MCO-OPT-8617 option)
Connector: BNC 75
Ω
Return loss: > 36 dB, 0.1 to 10 MHz
> 15 dB, 10 to 360 MHz
Insertion loss: < 0.2 dB, 0.1 to 180 MHz
< 1 dB, 180 to 360 MHz
On resistance: < 0.2
Ω
Cross-talk: < -70 dB, 0.1 to 10 MHz
< -80 dB at fsc
< -50 dB, 10 to 180 MHz
< -30 dB, 180 to 360 MHz
XLR Channels (MCO-OPT-8618 option)
Connectors:
Signal input: Sub-D 9 pin, female
Signal output: XLR 3 pin, male
Insertion loss: < 0.4 dB, 0.1 to 20 MHz
On resistance: < 0.2
Ω
Cross-talk: <-50 dB, 0.1 to 8 MHz
Remote Interface
Relay contacts for external alarm function.
Connector: 9 pin male sub-D
Voltage between contacts: < 50 V
Relay current: < 0.5 A
Switching power: < 60 W
Common mode voltage: < 50 V
Other contacts in remote connector: Internal pull up resistors, max. external voltage -0.5 V to +6 V.
Mechanical
19" rack mount cabinet. Height: 44 mm (1.73")
Width: 483 mm (19")
Depth: 490 mm (19.3”)
Weight:
4 kg (8.8 lbs)
Operating ambient temperature: +5 to +45°C
Power Supply
Voltage: 100-240 VAC
Frequency: 50/60 Hz
Power consumption: Maximum 15 W with all options installed