Instruction manual
MXS-EVO - MANUAL
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
MXS-EVO – Manual – Rev 1.7 - 38 -
Appendix B: FAQ
D: How is it possible to certify the various time references?
R: In order to certify a particular reference is better to have the device disciplined by GPS or from another stable
source.
In this way is possible to evaluate the jitter of the reconstructed PPS in different ways:
1. by asking the device the log of the last 6 hours
http://x.x.x.x/cgi-bin/savestability
2. by letting an external event logger collect the data (e.g. AON Console Manager)
3. by using a debug utility to retrieve the live values (distance, jitter, validity) and by post-processing them.
ftp://digiguest:guestd@www.digital-instruments.it/Server%20TCP%20v2.zip
To do so is simply necessary to launch the utility and specify the correct IP address of the device.
Is better to configure the utility with the following settings.
Add date an time OFF
Verbose debug ON
Continuous save ON