IP Camera (Network Camera) User Manual 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Important Safeguards and Warnings Do not place heavy objects on the DVR. Do not let any solid or liquid fall into or infiltrate the DVR. Please brush printed circuit boards, connectors, fans, machine box and so on regularly. Before the dust cleaning please switch off the power supply and unplug it. Do not disassemble or repair the DVR by yourself. Do not replace the components by yourself.
Catalogue Chapter One: Product introduction 1.1 Product summary The IP cameras can be applied as a part of a safety surveillance network. With the professional network video surveillance software it achieves the strong network communication ability and telecommunication ability. And IPC can individually work also. The series DVR is designed specially for security and defense field which is an outstanding digital surveillance product. It introduces embedded LINUX operating system which is more stable.
·with analog output interface can do surveillance through device of monitor or DVR, etc. Storage ·Max support TF card with 32G (part of model support) for local storage of snapshot image.
Chapter Two: Open case checking and cable connection 2.1 Open case checking When you receive this product, Firstly, check model No. on product is the same as what you ordered; Then, check if there is obvious damage on packing; the protective material used for packing can afford most unexpected strike during transportation; Finally, please take out IPC and remove the protective covers to check if there is obvious damage. 2.
2.4 Video output connection 2.4.1 choose and connect video output device 1.BNC output: BNC video output is divided into: PAL/NTSC BNC(1.0VP-P ,75Ω),can be connected to monitor or surveillance integrated equipment such as DVR, etc. BNC output can support preview of the monitor image only. Make sure the stable and reliable of transmission link: The video transmission line should adopt high quality coaxial pair which is chosen by the transmission distance.
Chapter Three: IE log-in basic operation Remark: keys in grey means do not support 3.1 Boot Connect to power, then IPC is auto boot. Remark:1. Make sure that the input voltage corresponds with the switch of the DVR power supply. 2. Power supply demands: 220V±10% /50Hz. Suggest using the UPS to protect the power supply under allowable conditions. 3.2 Reboot Reboot IPC is divided into soft reboot and hard reboot.
log-in user to provide related function. Default IP address:192.168.1.10,subnet mask:255.255.255.0,gateway:192.168.1.1 When device ex-fty, there are 3 preset users : admin、guest、default,default password is none, admin is preset as super authority user, guest and default is preset with authority of preview and playback, admin and guest user can modify password but not authority, default is the user default log-in, can modify authority but not password Pic : 3.
At preview page, can shows date, time and channel titile. 3.5 Setting menu at top side ,,will come out window as pic:3.3. setting menu On preview mode, click function including: Record, Alarm, System, Advanced, Info. Click icon at bottom side will enter related next menu of this function. Pic: 3.3 shortcut menu 3.5.1 Record Record function including: device record and snapshot settings. 1. Record setting Device should install TF card to realize this function.
Pic: 3.4 Record setting Pic: 3.5 Snapshot setting 10 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
3.5.2 Playback To play the video file in TF card, can click at upper left side on monitor page, to enter video playback page. Remark: Device normal playback, the TF card that used for video storage should be set as read/write or read only (please refer to HDD manage). Pic 3.6 Playback 【Playback control button】see detail in below chart; Button Function Button Function Play Pause Slow-play Fast-play 11 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Previous frame Next frame Stop Chart 3.1 playback control button list Remark:Playback by frame should under the status of playback pause. 【Operate tips】to show the button function when cursor point it Special feature: Partial enlargement:when single view full screen playback, can use right button to choose any size of area from the image, click left button in the chosen area, can enlarge this area to playback, double click left button will exit. 3.5.
Pic: 3.7 Color setting 3.6 Log Show alarm information and operation record, if u tick at lower left side, when alarm happens, window tip will auto come out. 13 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 3.8 Log information 14 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Chapter Four: Main Menu 4.1 Main menu guideline Main Menu Submenu Record Function summary Set record config, record type, record period, etc. Record Snapshot Set snapshot period, type , etc. Set motion detect alarm channel, sensitivity, area, linkage Video parameters: alarm output, snapshot, recording, PTZ, email motion sending, ftp upload, etc. Set video blind alarm channel, sensitivity, linkage parameters, Video blind alarm output, snapshot, recording, PTZ, email sending and ftp upload, etc.
Set encode mode: encode mode, resolution, frame rate, bit Encode rate, image quality, code stream value, I frame interval parameter, video/audio enable. Set basic net parameter, and DHCP 、DNS parameter , Network auto-gain IP address, network high-speed download, net transmission tactics ARSP、Mobile monitor、UPNP、FTP、WiFi、3G、alarm center、 Net service RTSP、PPPOE、NTP、Email、IP authority、DDNS parameter, etc.
Import & Config import, Config export, Log export Export Upgrade Reboot HDD info To do net upgrade via IE or client software IPC soft reboot Show ttl space of HDD, type, space left, record time, etc Can base on record type and time to search log, can clear the Info Log log information Version Show alarm input output, system version, build date, etc 4.2 Record Device do operation regarding record, including: record & snapshot. 4.2.
Pic: 4.1 Record setting 【Length】to set the length of each recording file between 1-120min, default is 60min; 【PreRecord】to record 1-30s before motion happens (time length may slight different due to bit rate) 【Record control】set recode type: timing, manual & stop Timing: Record according to the set video type (regular, detect and alarm)and time period.
file type is “M”. Alarm:Trigger the external alarm signal in the set time section. When above alarm is set as opening recording, the “detection recording” state is on. The video file type is “A”. Remark:related alarm setting, please refer to chapter 4.3 alarm part. 4.2.2 Snapshot storage Setup snapshot parameters for different channels.At first time it's set for 24hours snapshot continuously, pls go to Main Menu->Record->Snapshot Storage for appropriate settings.
Manual: No matter what is the current status, once choose "manual" ,it will have snapshot at related channels. Stop: No matter what is the current status, once choose "stop", it will stop snapshot at related channels. 【Period】Set normal record period, it only startup Snapshot Storage at set period.
Pic 4.3 Alarm function 4.3.1 Motion detect When system detects the motion signal that reaches the set sensitivity, the motion detect alarm and the linkage function is enable. 21 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.4 motion detect setting interface 【Enable】 means enable motion detect function, enable it firstly then can do related setting. 【Sensitivity】base on sensitivity, can set 6 grades: ,the higher of sensitivity to the moving objects, the easier to sense the motion happens; 【Region】ClickSetting,enter the setting region of PAL22X18,light blue region is the guard area of motion detect, dark blue region is the unguard area (show the monitor page), see pic 4.5.
Pic: 4.5 region setting 【Period】Trigger the motion detect signal in the set time section, see pic:4.6. You can set according to week or set uniformly. Each day is divided into four time sections.tick , mean setting is valid. 23 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic 4.6 Time Period setting 【Interval】Only one alarm signal is turned on even there are several motion detect signals in the set interval 0-600s. 【Alarm output】Start the external equipment of corresponding linkage alarm when the motion detect alarm is turned on.; 【Delay】Delay a few moments and stop when the alarm state is turned off. The range is 10~300 seconds.
Pic: 4.7 PTZ linkage 【Delay】When alarm is over,recording will last some seconds(10~300sec),then stop.; 【EMAIL sending】tick ,means when alarm happens link email sending to inform user. Remark:sending email, need to do related setting at【Net service】. 【FTP upload】tick ,means when alarm happens, if record or snapshot channel was chosen, the record file and snapshot image will be uploaded to the appointed position. Remark:FTP upload, need to do related setting at【Net service】. 4.3.
Pic: 4.8 video blind Setting detail : refer to chapter 4.3.1 motion detect. 4.3.3 Video lost When the equipment can not obtain the channel video signal, the video loss alarm is turned on and the linkage function is enable. 26 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.9 Video lost Setting detail: refer to chapter 4.3.1 motion detect. 4.3.4 Abnormal Analyze and detect the software and hardware of current device, when abnormal issue was detected, device will make related respondence. 27 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.10 abnormal 【Event type】choose event type at drop-down box, 【Enable】tick to enable,open abnormal deal function, setting is valid only if it is enable. 4.4 System setting To set parameter of all kinds of functions, setting including: General、Encode、Network、Net service、GUI display、PTZ config/RS485、RS232、Camera parameter. 28 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
4.4.1 General setting Pic: 4.11 General setting 【System time】set current date and time of IP Camera.
【DST】Tick DST, then click 【setting】, will come out window as pic: 4.12 & pic:4.13, to set the start time and end time of summertime via week or date. Pic:4.12 DST (Week) setting Pic:4.13 DST(Date) setting 4.4.2 Encode Seting Set video/audio encode parameters, including image parameters of record file, remote monitor, etc.
Pic: 4.14 Encode setting Encode setting 【Compression】Standard H.264MP; 【Resolution】show types of resolution: D1/HD1/CIF/QCIF; 【Frame rate】adjustable, real-time standard is: PAL,25 fps NTSC,30 fps; 【Bit rate type】you can choose CBR or VBR, image quality have 6 grades to choose under VBR type, then you can manual choose the bit rate value under CBR type.
【audio/video】the icon was all ticked, means audio & video combine stream 4.4.3 Network setting Pic: 4.15 Network setting 【Net card】you can choose wired net card; 【DHCP enable】to auto get IP address(not suggested); Remark:need to set up DHCP server in advanced.。 【IP address】set IP address of device, default IP address is: 192.168.1.10; 【subnet mask】set subnet mask of device, default subnet mask is:255.255.255.0; 【default gateway】set default gateway of device, default gateway is:192.168.1.
【TCP port】default is 34567; 【HTTP port】default is 80; 【high speed download】Network high speed download; 【Transfer policy】there are 3 policies, adaptive, quality preferred, fluency preferred. Base on different setting, code stream is auto-adjusted, adaptive is eclectic between quality and fluency, also considers fluency when the quality is not greatly influenced.
Pic: 4.17 PPPOE Enabe:Tick means chosen, enable it firstly, then the setting is valid Input user name and password that provided by ISP(Internet server provider), save it and reboot device, after reboot, IPC will auto connect to network by the way of PPPoE, if it is successful【IP address】will be changed to the dynamic WAN IP that just get. Operation:PPPoE dial up successfully,check【IP address】,to get current IP of device, then access this device by this IP from client side. 【NTP setting】 Pic: 4.
GMT-10 Alaska GMT-9 Pacific time GMT-8 US mountain time GMT-7 US central time GMT-6 US eastern time GMT-5 Atlantic time GMT-4 Brazil GMT-3 Atlantic central GMT-2; Update period:The same with the NTP server check interval. Default: 10minutes 【EMAIL setting】 EMAIL sending is used for sending alarm information and snapshot picture to appointed mailbox when alarm link to snapshot. 4.
When choose the white list, only the IP in the list can connect to IP camera, list can support 64 IP setting; When choose the black list, mean the IP in the list can not access IP camera via net, list can support 64 IP setting. Can tick to choose and delete the set IP. Pic: 4.20 IP authority setting(black list) Pic: 4.21 IP authority setting(white list) 【DDNS】 36 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.22 DDNS setting To analyze server via dynamic domain name, choose DDNS type Host domain name:Provide the domain name registered by DDNS; Server domain name:the domain name that analyze server; User name:Provide the account registered by DDNS. Password:Provide the password registered by DDNS.; When the DDNS is successfully configured and start, you can connect the domain name in the IE address column to visit.
【Remote path】 :the directory to upload file Remark:the user should have the authority to upload file to server firstly. 【ARSP】 Startup DDNS server to add devices and manage it in the DDNS server Pic: 4.24 ARSP setting 【type】 :choose DNS 【Enable】 :tick means chosen, setting is valid only when it is enable.
Pic: 4.25 Alarm center setting 【Protocol】protocol type is GENERAL; 【Enable】tick means chosen, setting is valid only when it is enalbe 【Server IP】IP address of Alarm Server; 【Port No】Port No. of device 【Alarm report】tick 【Log report】tick means chosen, report alarm information to server means chosen, report log information to server 【Mobile monitor setting】 To visit the device by mobile,pls make a router mapping of this port and use CMS to monitor and operate it by protocol. Pic: 4.
【Port】port no for mobile monitor, which you need to make a router mapping of if want to visit it by mobile 【UPNP】 UPNP protocol can auto port forwarding on router,make sure UPNP is enable on router before use it. Pic 4.
Pic: 4.28 GUI display 【Channel Name】Click the channel name modify button and enter the channel name menu. Modify the channel name. The 16 Chinese characters and 25 letters are supportive. 【Time title】tick 【channel title】tick means chosen, to shows the system time on monitoring page; means chosen, show channel No at monitoring page. 【record status】tick means chosen, show the record status on monitoring page 【Alarm status】tick means chosen, show the alarm status on monitoring page.
【 Region Cover 】 tick , choose region cover quantity, then click setting ,enter related channel, user can use mouse to choose any size of cover region, (the covered region, video output should be in black) 【Time title】与【Channel title】set time title and channel title whether need be show out and the position to show. Pic: 4.29 region cover setting 42 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.30 Channel and time title setting 43 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
4.4.6 RS232 Pic: 4.31 RS232 【Serial Port Function】Common serial port is used to debug and update program or set up specific serial port. 【Baud rate】Choose the corresponding baud rate length 【Data bits】Include 5-8 options. 【Stop bits】Include 2 options; 【Parity】Include odd, even, mark, space.。 44 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
4.4.7 Camera parameter Pic: 4.32 camera parameter 【Expose】can choose automatic(0.
【IR_CUT】can choose automatically switch or IR synchronous switch, default is automatically switch 【Mirror image】tick 【Over turn】tick 【Anti-flicker】tick ,means enable the convert of left and right of monitoring page ,means enable the convert of up and down of monitoring page. ,enable anti-flicker to the fluorescent light. 【Front-end Command】fill in command and send out, front end of IP camera will carry out this command 4.
Pic: 4.33 HDD manage 4.5.2 Account Manage the user authority of this device Remark:1. The character length is 8 bytes at most for the following user and user team name. The blank ahead or behind the character string is invalid.The middle blank in the character string is valid. Legal characters include: letter, number, underline, subtraction sign, dot. 2. There is no limit in the user and user group. You can add or delete the user group according to user definition. The factory setup include: user\admin.
Pic: 4.34 Account 【Modify User】Modify the existed user attribute. 【Modify Group】Modify the existed team attribute. 【Modify Password】Modify the user password. You can set 1-6 bit password. The blank ahead or behind the char string is invalid. The middle blank in the char string is valid, Note:The user who possess the user control authority can modify its own or other users password Pic: 4.35 Modify password 48 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
【Add user】Add a user in the team and set the user purview. Enter the menu interface and input the user name and password. Choose the team and choose whether cover using the user. Cover using means that the account can be used by multiple users at the same time. Once choose the team the user purview is the subclass of the team. We recommend that the common user’s purview is lower than the advanced user. Pic: add user 【Add Group】Add a user team and set the purview.
Pic: 4.37 add group 【Delete user】Delete the current user. Choose the user and click delete user button. 【Delete Group】Delete the current group. Choose the group and click delete group button. Pic: 4.38 delete group 4.5.3 Auto-maintain The user can set the auto reboot time and auto file deleting time limit. 50 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.39 auto maintain 4.5.4 Default The system restore to the default setup. You can choose the items according to the menu.) 51 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.40 default 52 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
4.5.5 Upgrade Pic: 4.41 system upgrade 【upgrade file】to select upgrade file via IE or client software to do upgrading. 4.5.6 Reboot To do soft reboot of IP camera 4.6 Device info Shows information of device, including:HDD info、Log , Version 4.6.1 HDD Info Display the hard disk state: type, overall capability, residual capability, the recording time and so on.。 53 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.42 HDD info Tips:○ means that the hard disk is normal. X means that the hard disk is broken-down.- means that there is no hard disk. If the user need to change the damaged hard disk, you must shut down the DVR and take up all the damaged hard disks,then install a new one. * behind serial number means the current working disk such as 1*. If the corresponding disk is damaged, the information will show “?”. 4.6.
Pic: 4.43 Log info 4.6.3 Version Display the basic information such as hardware information, firmware version, built date, serial Number, and so on. 55 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.
Pic: 4.44 version info 56 12000 Ford Road, Suite 110 Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.