Technical data
RZ56 Storage Expansion Box 55
6.1 General SCSI Bus Configuration Information
The following is general information on the SCSI bus:
• The external SCSI port on the back of the system box can be
connected with one to six drives. However, system performance is
slower when more than four drives are connected.
• The BA42 enclosure storage expansion box can contain one or two
drives. Make sure you configure the second drive’s SCSI ID if the box
contains a second drive.
• The maximum distance for the cable between the external SCSI port
and the last storage expansion box is 18 feet (6 meters).
• The SCSI ID address determines the priority of devices on the SCSI
bus. SCSI ID 7 is the highest priority and SCSI ID 0 is the lowest
priority.
6.2 Connecting the RZ56 in a BA42 Storage
Expansion Box
The BA42 storage expansion box connects to the system box through
the external SCSI port. (Figure 6–2) and (Figure 6–3) show how the
BA42 storage expansion box connects to the system box. The SCSI cable
connects to either of the two ports on the back of the expansion box.
However, the SCSI terminator must be installed on the unused connector
unless another expansion box is daisy-chained. If the SCSI port already
has a box connected to it, use another cable to connect the new storage
expansion box to the last box on the daisy chain. Be sure to move the
terminator on the unused connector on the back of this last storage
expansion box in the daisy chain.