Technical data

48 VAXstation 3100 (Model 38) System
4.13 Power Supply Removal
To remove a power supply:
1. Remove the system box cover (Section 4.3).
2. Remove the drive plate (Section 4.7).
3. Disconnect the power cable from the system module.
4. Unscrew the four screws (Figure 4–20).
CAPTIVE SCREW
CAPTIVE SCREW
ALLEN-HEAD BOLTS
MA-X0808-88B
POWER SUPPLY
Figure 4–20 Power Supply Screw Locations
5. Lift the power supply out of the system box.