Technical data
Utilities (T 74 and T 76) 19
>>> TEST 76
>>>
ScsFlpFmtter
PV_SCS_FMT_CHN
PV_SCS_FMT_ID
(0=SCSIA \ 1=SCSIB)? 0 Enter SCSI bus.
Enter SCSI ID of RX23.
Enter a 1 for yes, 0 for no.
Formatting diskette
RX23 format checked OK.
Diskette is formatted
successfully.
(0,1,2,3,4,5,6,7)? 5
PV_SCS_FMT_RUsure (1/0)? 1
PV_SCS_FMTing...
PV_SCS_FMT_CHKpass...
PV_SCS_FMT_SUCC
Example 3–1 Formatting an RX23 Diskette
3.1.1 Diskette Formatter Messages
Table 3–2 lists all the formatter messages and gives an explanation for
each.
Table 3–2 Diskette Formatter Messages
Formatter Message Explanation
PV_SCS_FMT_CHKpass A check pass is being done on the diskette.
PV_SCS_FMT_CHN Enter the SCSI bus that is connected to the
RX23/SCSI adapter assembly. Enter 0 for the
SCSI-A bus or enter 1 for the SCSI-B bus.
PV_SCS_FMTing The RX23 diskette is being formatted.
PV_SCS_FMT_RUsure The formatter uses this question as a safety
check. Enter 1 for yes if you want to format the
diskette, otherwise enter any character other
than 1 to abort the formatter.
PV_SCS_FMT_ID Enter the SCSI ID of the RX23. Usually the
RX23 ID is set for ID 5.
PV_SCS_FMT_SUCC The diskette has been successfully formatted.