Technical data
14 Troubleshooting
SCSI−A 2C2C.0001
FFFFFF05 FFFFFF05 00000001 00000001 FFFFFF05 00000001 FFFFFF03 ...
offline RZ23
drive
RZ23
drive
offline RX23
drive
SCSI−A
controller
offline
Example 2–2 Self-Test Results on the SCSI-A Bus
If a Self-Test Indicates an Error
The error may be on the RX23 drive, on the other drives on the SCSI-A
bus, or on the SCSI-A bus controller. To determine which device is faulty,
examine the status codes of the individual drives. The SCSI IDs are
numbered 0 through 7 from left to right (for example, the RZ23 disk drive
is located at SCSI ID 2 and the RX23 diskette drive is located at SCSI ID
5). Table 2–3 lists the normal status codes for each SCSI device available
on the SCSI bus.
Any code other than those listed indicates an error in the device at that
SCSI ID.
Table 2–3 SCSI Devices Self-Test Status Codes
Status
Code SCSI Device
FFFFFF05 Device is offline or not installed at this SCSI ID
If a drive’s status code indicates FFFFFF05, check the drive’s
cabling and power, then retest. If the code is still FFFFFF05 after
retesting, then replace the drive.
FFFFFF03 SCSI bus controller
FFFFFFFF Device not tested - possible SCSI bus controller error
00000001 RZ22, RZ23, or RZ56 disk drive
00000001 RX23/SCSI adapter assembly
01000001 TZ30 or TK50 tape drive
05000001 RRD40 compact disk drive