Technical data
Testing 3
Table 1–1 lists the test numbers and the devices that are tested during
that particular test. To look at the status of a device, display the
configuration table.
>>> TEST 50
The configuration table lists every device in the system and also lists
the results of the power-up tests and self-test. It is updated each time
a self-test is run (mouse status is not updated). Remember that the
configuration table contains the results of the power-up tests and self-test
and not the results of the system exerciser.
Table 1–1 Power-Up and Self-Test Commands
Test Mnemonics Device
T F MONO Base video
T E CLK Time-of-year clock
T D NVR Nonvolatile random access memory (RAM)
T C DZ Serial line controller
T B MEM Memory
T A MM Memory management unit
T 9 FP Floating point unit
T 8 IT Interval timer
T 7 SCSI-A SCSI-A bus controller
Internal RZ22 and RZ23 disk drives
Internal TZ30 tape drive
Internal RX23/SCSI adapter assembly
T 6 SCSI-B SCSI-B bus controller
Internal RZ22 and RZ23 disk drives†
Internal RRD40 compact disk and adapter board†
RZ55 storage expansion box
RZ56 storage expansion box
TK50Z-GA storage expansion box
RRD40 storage expansion box
T 5 SYS Interrupt controller and Ethernet ID ROM
T 4 8PLN Option module (8-plane graphics module)
Model 38 systems only
†Model 48 systems only