Specifications
EA:PXG shows that the module is a mid 3D graphics
accelerator. When a mid 3D graphics accelerator module is
in the system, option slot 0 does not appear in the display.
PXG_T shows that the module is a high 3D graphics
accelerator. When a high 3D graphics accelerator module
is in the system, neither option slot 0 nor option slot 2
appears in the display.
SCSI shows that you have a SCSI option module.
A SCSI module is always present in base slot 5.
In addition, a SCSI option module can be installed in any of
the three option slots.
enet: shows that you have an Ethernet module.
ThinWire Ethernet is always present in base slot 6.
In addition, a ThickWire Ethernet module can be installed
in any of the three option slots on the system unit.
In the sample display, a ThickWire Ethernet option module
is present in option slot 0.
If the module you have just installed does not show up on the
configuration display, turn to Chapter 9 for troubleshooting
procedures.
To remove an option module
1. If necessary, follow the instructions that came with your
worksystem software to shut down the software.
2. Turn off the system unit by pressing the 0 on the on/off
switch on the back of the unit.
3. Remove the cover from the system unit.
4. Place the loop on the antistatic wrist strap around your
wrist and clip the other end to the metal frame that
encloses the system unit.
5. Unscrew the two screws that hold the option module in
place against the back of the system unit and the two
screws that hold the module on its support posts.
4–22 Internal Hardware Options