Specifications

Table A-38 (Cont.). RZ56 SCSI Hard Disk Drive Specifications
Start time (maximum) 20 sec maximum
Stop time (maximum) 20 sec maximum
Interleave 1:1
Table A-39. RZ56 SCSI Hard Disk Drive Operating Conditions
Temperature range
1
10° C to 55° C (50° F to 131° F)
Relative humidity 8% to 80%, noncondensing
Maximum wet-bulb temperature 25.6° C (78° F)
Minimum dew-point temperature C (36° F)
Altitude –1,000 to 15,000 ft at 36° C (96° F)
1
Reduce maximum temperature by 1.8° C (3.24° F) for each 1,000-meter increase in altitude.
Table A-40. RZ56 SCSI Hard Disk Drive Nonoperating Conditions
Temperature range 40° C to 66° C (– 40° F to 151° F)
Relative humidity 8% to 95%, packaged
Maximum wet-bulb temperature 46° C (115° F), packaged
Minimum dew-point temperature C (36° F)
Altitude 1,000 to 40,000 ft at 36° C (96° F)
Equipment Specifications A–21