Specifications

Table A-18 (Cont.). VRT19 Monitor Specifications
Vertical rate timing
(4 pixel nibble clock timing)
Frequency 66.4743 Hz
Front porch 3 horizontal lines
Sync pulse 3 horizontal lines
Blanking interval 39 horizontal lines
Active video 14.4915 ms
Vertical period 15.0434 ms
Power
AC input voltage 90-132/198-264 Vac
Frequency 47 to 63 Hz
Power consumption 150 watts maximum
Table A-19. VRT19 Monitor Operating Conditions
Temperature range 10° C to 40° C (50° to 104° F)
Relative humidity 10% to 95%
Maximum wet-bulb temperature 32° C ( 89° F)
Minimum dew-point temperature C (36° F)
Altitude up to 10,000 ft
Table A-20. VRT19 Monitor Nonoperating Conditions
Temperature range 40° C to 66° C (– 40° F to 150° F)
Relative humidity 10% to 95%
Maximum wet-bulb temperature 46° C (115° F), packaged
Minimum dew-point temperature C (36° F)
Altitude 12,780 m (50,000 ft)
Equipment Specifications A–11