Table A-14 (Cont.). VR299 Monitor Specifications
– Back porch 1,680 ns
– Blanking interval 3.69 s maximum
– Active video 14.8 s
– Horizontal period 18.5 s
Vertical rate timing
– Frequency 60 Hz
– Front porch 0 horizontal lines
– Sync pulse 3 lines
– Blanking interval 37 lines
– Active video 16.0 ms
– Vertical period 16.67 ms
Power
– AC input voltage (switch
selectable)
88-132/185-254 Vac
– Frequency 50/60 Hz
– Power consumption 150 watts maximum
Fuse 3.2 A for 120 V system
1.6 A for 240 V system
Table A-15. VR299 Monitor Operating Conditions
Temperature range 10° C to 40° C (50° to 104° F)
Relative humidity 10% to 95%, noncondensing
Maximum wet-bulb temperature 32° C ( 89° F)
Minimum dew-point temperature 2° C (36° F)
Altitude 2,400 m (8,000 ft) at 36° C (96° F)
A–8 Equipment Specifications