Specifications

Table A-1. System Unit Description
Weight Height Width Depth
System unit 12.7 kg
(28 lb)
92 mm
(3.62 in)
509.5 mm
(20.06 in)
434.8 mm
(17.12 in)
Table A-2. System Unit Specifications
Input voltage Adjust to 100 to 120 Vac to 220-240 Vac
Input current 5 amps at 100 to 120 Vac
2.4 amps at 220 to 240 Vac
Power
Frequency 50 to 60 Hz
Heat dissipation 359 watts maximum
Table A-3. System Unit Operating Conditions
Temperature range 10° C to 40° C (50° F to 104° F)
Temperature change rate maximum 1 C (20° F) per hour
Relative humidity 20% to 80%, noncondensing
Maximum wet-bulb temperature 28° C (82° F)
Minimum dew-point temperature C (36° F)
Altitude 2400 m (8000 ft) at 36° C (96° F)
Table A-4. System Unit Nonoperating Conditions
Temperature range 40° C to 66° C (– 40° F to 151° F)
Relative humidity 10% to 95%, noncondensing
Maximum wet-bulb temperature 46° C (115° F), packaged
Minimum dew-point temperature C (36° F)
Altitude 4900 m (16,000 ft) at 36° C (96° F)
A–2 Equipment Specifications