Specifications

Workstation Site Requirements
For your DECstation 5000 Model 200 workstation to function
efficiently, your work environment must meet the requirements
listed here.
Caution: Failure to meet these requirements can damage equipment.
Temperature
Keep the temperature around the workstation between 50
and 104 degrees Fahrenheit (10 and 40 degrees Celsius).
Set up your workstation away from heaters,
photocopiers, and other sources of heat.
Protect your workstation from sunlight.
Allow air to flow freely around your workstation to keep
heat from building up and damaging your equipment.
Leave 4 inches (10 cm) of space between system unit
vents and other objects.
Leave 3 inches (8 cm) of space between monitor vents
and other objects.
Humidity
Keep relative humidity within the range of 10 to 80 percent.
Cleanliness
Keep your work area as dust-free as possible.
1–2 Getting Started