Specifications
enet: shows that you have an Ethernet option module.
A ThinWire Ethernet module is always present in base
slot 6. In addition, a ThickWire Ethernet module can be
installed in any of the three option slots on the system unit.
To display the configuration for a particular slot, type cnfg and
the slot number at the console prompt (>>). Then press Return.
A configuration display similar to that in Figure 8-5 appears on
the screen.
In the display in Figure 8-4, a ThickWire Ethernet option
module is present in option slot 2.
>>cnfg 5
5: PMAZ-AA DEC T5.2a TCF0 (SCSI = 7)
---------------------------------------------------
DEV PID VID REV SCSI DEV
===== ================== ========== ====== ========
rz1 RZ55 (C) DEC DEC 0700 DIR
rz4 RRD40 (C) DEC DEC 0700 CD-ROM
tz6 SEQ
>>
Figure 8-5. Sample slot configuration display
In Figure 8-5, the line that begins with a number followed
by a colon tells you the number of the slot for which the
configuration is being displayed. In the example in Figure 8-5,
the display is the configuration for the SCSI module in base
slot 5.
The entries in the first column of the display tell you what
drives are present and what their ID numbers are. Entries that
begin with
rz are for hard disk and optical compact disc drives.
Entries that begin with
tz are for tape drives.
The entries in the last column tell you what type the drive
is.
DIR indicates that the drive is a hard disk drive. CD-ROM
indicates that the drive is an optical compact disc drive. SEQ
indicates that the drive is a tape drive.
The in the sample display that contain
5: and tz6 show that
a TK50 drive with SCSI ID number 5 is connected to a SCSI
module located in base slot 5 on the system unit.
8–12 Starting and Testing Workstation Hardware