Self-Tests
B.1 Console’s Configuration Display Utility (T 50)
The results of the self-test are available through the console’s
configuration display utility (T 50). The general format is as pictured
below.
>>> T 50
KA43-A V1.0
ID xx-xx-xx-xx-xx-xx
MONO 0000.0xxx (test F)
CLK 0000.00xx (test E)
NVR 0000.00xx (test D)
DZ 0000.xxxx (test C)
0000xxxx 0000xxxx 0000xxxx 0000xxxx kkkkkkkk mmmmmmmm
MEM 000y.00xx (test B)
ssssssss 0000mmmm
FP 0000.000x (test 9)
IT 0000.000x (test 8)
SCSI A wxy0.wxyz (test 7)
ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt
SCSI B wxy0.wxyz (test 6)
ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt ddmmsstt
SYS 0000.0xxx (test 5)
8PLN 0000.0001 V1.0
NI xxxx.yyyy (test 1)
B.2 NI (test 1)
The NI status has one longword of status and error information,
formatted as follows:
xxxx.yzzz
where y is the subtest number, zzz is the subtest status, and xxxx has
variable meaning depending upon the value of y.