Service manual
Troubleshooting 11
Example 2–1 shows the second 8-digit number of the MEM display in
the configuration table. Each digit represents a SIMM memory module.
A code other than 0 in any of the digits indicates an error on a memory
SIMM.
Each digit contains the status of four banks of memory (1 bank = 1 Mbyte
of memory).
4−Digit Error Code
Bit map representation of the failed
memory bank on a memory module if not
all zeros (0000000).
See Table 2−1 to determine the
failed SIMM memory module.
This field is displayed only when a failure
is detected on one of the SIMM modules.
?? MEM 0010.0020
01000000 00000000
8−Digit Error Code
Hexadecimal representation of the
total amount of memory in the system
as listed below.
4 Mbytes
8 Mbytes
12 Mbytes
16 Mbytes
20 Mbytes
24 Mbytes
28 Mbytes
32 Mbytes
00400000
00800000
00C00000
01000000
01400000
01800000
01C00000
02000000
Example 2–1 MEM Error Display in the Configuration Table