Installation guide

WS33P013
Yes
setenv console s.
Press Return.
Connect the alternate
terminal to the system unit.
A
(Continued)
B
(Continued)
Type
End
Troubleshoot according to
the error messages that
appear on the terminal.
Replace any FRU that
reports an error.
Reconnect any SCSI
devices that you
disconnected. Reset the
environment variables.
End
Replace the TURBOchannel
module in the slot number
that appears on the left
LEDs.
Reconnect any SCSI
devices that you
disconnected. Reset the
environment variables.
End
If the entire LED display is
0000 0000, replace parts of
the graphics hardware one
by one until the problem is
corrected.
Does the power-up
self-test stop with the
right LEDs equal to
0011 or 0010?
No
Figure 2-27 When ULTRIX is running but the
monitor has no display, 3 of 3
2–44 TROUBLESHOOTING TOOLS