Installation guide
Table 2-8 SCC pins test codes and
descriptions
(code: description) Meaning
1:LnN Invld param [xx] The loopback
specifier was invalid.
The error occurred
on serial line N.
xx is the first two
characters of the
invalid value.
2:LnN Strtup R-xx
xptd=yy actl=zz|pins|
Test failed to
generate the expected
SCC status bits.
The error occurred
on serial line N. xx
is the number of
the SCC register
that contains the
status bits. yy is the
expected status bits.
zz is the actual status
bits. |pins| is the
pin pairs tested.
3: LnN xxxxx Pins failed to respond
properly. xxxxx is the
numbers of one or
more pin pairs that
failed the test.
2–16 TROUBLESHOOTING TOOLS