Technical data
System Test Error Messages, Continued
Format Meaning
FRU Field replaceable unit (hexadecimal if FRU
gotten from request sense packet)
CMD SCSI command that failed (hexadecimal)
PHS SCSI Bus phase at time or error
INF Informational value (same as those reported
by the self-test...hexadecimal)
LBNSTRT Starting logical block number of failed
transfer (hexadecimal)
XFERSIZ Transfer size in blocks of failed transfer
(hexadecimal)
This information is followed by any available request sense data.
Synch
Communications
Device
Errors reported for the system test are the same as those reported
for the extended self-test, in addition to errors that may be
reported by the VAXeln kernel service.
COMM
Errors reported for the system test are the same reported for
extended test in addition to errors that may be reported by the
VAXeln kernel service.
DZ
The following is the DZ error message format.
?? 3 DZ 0 ABCD 0 00:00:00:00
ABCD are the four DZ lines. The error codes are identical for
each line.
A (line 3) printer port
B (line 2) 25 pin connector
C (line 1) Mouse
D (line 0) Keyboard
0 00:00:00:00 test run time
Continued on next page
A–86