Self-Test Error Messages, Continued
Table A–21 Synch Communications Self-Test Sequence
Numbers
Test Number
Decimal Hexadecimal Routine Description
01 01 imp_exc Exception vector
initialization
02 02 imp_vec User interrupt vector
initialization
03 03 imp_rdb Local register RDB
initialization
04 04 imp_pub_
init
Up block initialization
05 05 imp_op_
init
Option register
initialization
06 06 imp_br_init Base register
initialization
07 07 imp_cs_
switch
Power-up switch
initialization
08 08 imp_cfg Get hardware
configuration
09 09 imp_scr_
init
System Control register
initialization
10 0A imp_core MC68302 Core
confidence test
11 0B imp_dwcn Watchdog timer counter
clear
12 0C imp_aport_
init
Port A initialization
13 0D imp_bport_
init
Port B initialization
14 0E imp_cisdn ISDN Configuration
Continued on next page