Technical data
Self-Test Error Messages, Continued
Table A–20 (Continued) TURBOchannel Adapter Self-Test
Error Codes
Decimal Hexadecimal Meaning
0010 000A FIFO Not empty after retrieving
data
0012 000C Data read from FIFO does not match
loaded data
0014 000E Forced invalid reference error not
seen
0016 0010 Forced ERROR condition not seen
0018 0012 TCA Interrupt at VAX INT_REG not
set
0020 0014 Interrupt bit on TCA not set
0022 0016 ISR Was not entered on interrupt
0024 0018 FIFO Data was bad after DMA
TRIGGER read operation
0026 001A FIFO Data does not match loaded
data after DMA TRIGGER write
The TURBOchannel adapter self-test does not display extended
error information when an error occurs. Enter the SHOW ERROR
command to view the extended error information.
TURBOchannel error codes appear in the following format:
?? 013 13 TCA XXXX
The XXXX refers to the error code format.
Errors reported directly from the console are in decimal
format.
Errors displayed in response to the SHOW ERROR command
are in hexadecimal format.
Continued on next page
A–56