Technical data

Self-Test Error Messages, Continued
Table A–19 (Continued) Synch Comm Device Test Error
Codes
Decimal Hexadecimal Meaning
266 10A ROM Test error
268 10C FBUG Secure error-reserved
operation
270 10E Port PB3 Signal stuck high
272 110 Timer 3 not counting
274 112 Comm option diagnostics did not
complete
276 114 Comm option SDMA bus error
occurred
278 116 Timeout waiting for IRQ assertion
280 118 Transmit restart of 10 exceeded
TURBOchannel
Adapter
Self-Test Error
Codes
Table A–20 describes the TURBOchannel adapter decimal and
hexadecimal self-test error codes.
Table A–20 TURBOchannel Adapter Self-Test Error Codes
Decimal Hexadecimal Meaning
0002 0002 TURBOchannel Reset bit stuck at 1
0004 0004 Forced TURBOchannel Timeout not
seen
0006 0006 Timeout bit stuck at 1
0008 0008 FIFO Is empty after loading data
Continued on next page
A–55