Technical data
Self-Test Error Messages, Continued
Table A–19 (Continued) Synch Comm Device Test Error
Codes
Decimal Hexadecimal Meaning
222 DE Memory free error
224 E0 UTIL Invalid utility number
226 E2 UTIL Invalid cable code
DSW21 Comm. Timeout Failures
228 E4 Timeout comm option set response RA
230 E6 Timeout comm option clear command
CA
232 E8 Timeout comm option set scheduler
run SR
234 EA Timeout comm option set transmit
ready TR
236 EC Timeout comm option set receive
ready RR
238 EE Comm option exception occurred
240 F0 Comm option command register
timeout
242 F2 Comm option transmit clear to send
lost
244 F4 Test memory allocation error
246 F6 Test memory free error
248 F8 Comm option reported invalid
configuration
Continued on next page
A–53