Self-Test Error Messages, Continued
The FRU reported by all error formats is either 1 for the system
board FRU, or (100 + device_id*10 + logical unit number.
Table A–16 lists the information values reported by some
extended SCSI self-test errors. Hexadecimal values are used
for self-test.
Table A–16 SCSI Information Values
Information
Decimal Hexadecimal Meaning
1 1 Valid group code bit clear in
Controller status register
2 2 Valid group code bit set in Controller
status register
3 3 Terminal count bit clear in Controller
status register
4 4 Terminal count bit set in Controller
status register
5 5 Parity error bit clear in Controller
status register
6 6 Parity error bit set in Controller
status register
7 7 Gross error bit clear in Controller
status register
8 8 Gross error bit set in Controller status
register
9 9 Interrupt bit clear in Controller status
register
10 A Interrupt bit set in Controller status
register
11 B Selected bit clear in Controller
Interrupt register
Continued on next page
A–39