Technical data

Self-Test Error Messages, Continued
EXTENDED ERROR FORMAT B(h):
This error format is used by the register test.
001 000B aaaaaaaa bbbbbbbb cccccccc
Format Meaning
aaaaaaaa The error code
bbbbbbbb The address of register or location being
accessed
cccccccc Information about the error
EXTENDED ERROR FORMAT C(h):
This error format is used by the interrupt test.
001 000C aaaaaaaa bbbbbbbb cccccccc dddddddd eeeeeeee ffffffff
Format Meaning
aaaaaaaa The error code
bbbbbbbb Information about the error
cccccccc Contents of interrupt mask register
dddddddd Contents of interrupt request register
eeeeeeee Contents of controller status register
ffffffff Contents of controller interrupt register
Continued on next page
A–31