Technical data
Self-Test Error Messages, Continued
Table A–14 (Continued) NI Self-Test Error Codes
Decimal Hexadecimal Meaning
112 70 SGEC Address filtering: initialization
failed
114 72 SGEC Address filtering: transmit
failed
116 74 SGEC Address filtering: receive failed
118 76 SGEC Address filtering: packet
comparison failed
120 78 SGEC Address filtering: broadcast
filtering failed
122 7A SGEC Address filtering: promiscuous
mode failed
124 7C SGEC Address filtering: null
destination accepted
126 7E SGEC Address filtering: good logical
address rejected
128 80 SGEC External loopback:
initialization failed
130 82 SGEC External loopback: packet
comparison failed
132 84 SGEC External loopback: check NI
port connector
The NI self-test also returns extended error information when an
error occurs. This information is available by entering the SHOW
ERROR command. The first value is the FRU; the second value is
the extended error format number in hexadecimal. The remaining
values are in hexadecimal. The extended error format can be one
of several types.
Continued on next page
A–25