Technical data
Self-Test Error Messages, Continued
Extended Error Format:
This format displays when there is an invalidate filter RAM error.
001 0010 aaaaaaaa rrrrrrrr eeeeeeee
Format Meaning
001 The FRU number (system board)
0010 The format number
aaaaaaaa The failing invalidate filter address
rrrrrrrr The data read
Network
Interface
Table A–14 lists the decimal and hexadecimal error codes
returned by the network interface (NI) self-test. If an NI error
occurs, first verify that a loopback connector is installed on the
selected network port on the back of the system box or that the
network cable is firmly connected. Re-execute the NI self-test, if
necessary.
Table A–14 NI Self-Test Error Codes
Decimal Hexadecimal Meaning
16 10 Network Address ROM: read access
failed
18 12 Network Address ROM: null address
20 14 Network Address ROM: bad group
address
22 16 Network Address ROM: bad checksum
24 18 Network Address ROM: bad group 2
26 1A Network Address ROM: bad group 3
Continued on next page
A–22