Technical data

Self-Test Error Messages, Continued
Table A–9 (Continued) MEM SIM Module FRU Values
FRU
(decimal)
SIM
Module BANK
046 1H 1
047 0D 0
FPU
Table A–10 lists the floating point diagnostic decimal and
hexadecimal error codes.
Table A–10 FPU Self-Test Error Codes
Decimal Hexadecimal Meaning
258 102 MOVF Instruction test has failed.
260 104 Unexpected Exception has occurred
during MOVF test.
514 202 MNEGF Instruction test has failed.
516 204 Unexpected Exception has occurred
during MNEGF test.
770 302 ACBF Instruction test has failed.
772 304 Unexpected Exception has occurred
during ACBF test.
1026 402 ADDF2/ADDF3 Instruction test has
failed.
1028 404 Unexpected Exception has occurred
during ADDFx test.
1282 502 CMPF Instruction test has failed.
1284 504 Unexpected Exception has occurred
during CMPF test.
Continued on next page
A–18