Technical data

Self-Test Error Messages, Continued
Extended Error Format:
xxx 4 MEM yyyy
xxx 00a bbbbbbbb cccccccc dddddddd eeeeeeee
Format Meaning
xxx The FRU where the failure occurred
yyyy The error code in Hexadecimal
00a Extended error information format type
bbbbbbbb The contents of the Memory System Error
register (MSER)
cccccccc The failing address
dddddddd The expected data
eeeeeeee The data that was read
MEM SIM
Module FRU
Values
Table A–9 lists the MEM SIM module FRU values.
Table A–9 MEM SIM Module FRU Values
FRU
(decimal)
SIM
Module BANK
040 0A 0
041 1E 1
042 0C 0
043 1G 1
044 1F 1
045 0B 0
Continued on next page