Technical data

Self-Test Error Messages, Continued
OBIT
Table A–6 lists the OBIT self-test decimal and hexadecimal error
codes.
Table A–6 OBIT Self-Test error codes
Decimal Hexadecimal Meaning
6 6 Failed floating 1s and 0s data test
8 8 Failed verify background pattern =
AAAAAA, write 555555
10 A Failed verify second pattern = 555555,
write 0
12 C Failed verify background pattern = 0,
then write FFFFFF
14 E Failed verify second pattern =
FFFFFF, write 0 and good ECC
Continued on next page
A–13