Technical data
System Preparation, Continued
NOTE
After adding the new device or module, halt
the system when you first turn it on. Use
the diagnostic tests described in Chapter 5
to determine if the new device or module is
connected correctly.
4. Before adding a new device or module, review the
current system configuration. Record the current system
configuration information for reference. After adding the new
device or module, compare the new configuration with the
previous one to help verify that all devices are present and
functioning correctly.
To determine the presence of devices, test status, and the
quantity of memory inside the system, enter the following
command:
>>> SHOW CONFIG
Return
Configuration information similar to the following appears.
An explanation of the response is provided next to each line.
KA49-A V0.0-051-V4.0 ! System type and firmware revision
08-00-2B-F3-31-03 ! Ethernet hardware address
80 MB ! Total memory
DEVNBR DEVNAM INFO
------ ------ ----
1 NVR OK ! Non-volatile RAM
2 LCSPX OK
Highres - 8 Plane 4MPixel FB - V0.8
3 DZ OK ! Serial line controller
4 CACHE OK ! Cache memory
5 MEM OK ! Memory configuration
80 MB 0A,0B,0C,0D = 4 MB, 1E,1F,1G,1H = 16 MB
6 FPU OK ! Floating point accelerator
7 IT OK ! Interval timer
8 SYS OK ! Other system functions
9 NI OK ! Ethernet
10 SCSI OK ! SCSI and drives
0-RZ24 1-RZ25 2-RRD42 6-INITR
11 AUD OK ! Sound
12 COMM OK ! DSW21 communications device
Continued on next page
6–6