Technical data

System FRU Removal
Before Starting
Perform these preliminary steps before removing and replacing a
FRU.
Step Action
1 Verify that the symptom is not caused by improper
configuration or a loose cable.
2 Confirm with the customer that data has been backed
up. If not, the data could be lost (when a hard disk is at
fault).
3 Ensure that the operating system is shut down before
turning off the system or halting the CPU.
4 Enter the SHOW CONFIG command and write down the
following information:
System ROM version
Graphics type
Memory configuration
Verify that the configuration agrees with the
amount and type of memory modules present. If
the configuration does not agree, verify that the
memory modules are installed correctly.
SCSI devices and IDs
Verify that the configuration agrees with the actual
hardware. If the configuration does not agree, ensure
that the following are true:
SCSI IDs are all unique.
Cables are correctly installed.
The expansion box power is turned on first.
5 Wait three minutes after turning off a monitor before you
move or service it.
Continued on next page
6–3