Technical data

Product Fault Management, Continued
MEMCON 00010101
MEMORY CONFIGURATION:
MS44-AA Simm Memory Module (4MB)
Loc 0A
MS44-AA Simm Memory Module (4MB)
Loc 0B
MS44-AA Simm Memory Module (4MB)
Loc 0C
MS44-AA Simm Memory Module (4MB)
Loc 0D
_Total memory = 16MB
_sets enabled = 00000001
MEMORY ERROR STATUS:
SIMM MEMORY MODULES: LOCATIONS
0A & 0B
Set = 0(X)
Bank = B
MEMCON0 80000003
64 bit mode
Base address valid
RAM size = 1MB
base address = 00(X)
ANAL/ERR/OUT=TB1 TB1.ZPD
This example provides an example of a device attention entry.
V A X / V M S SYSTEM ERROR REPORT COMPILED 17-FEB-1992 05:32:21
PAGE 1.
************************** ENTRY 60. ***************************
ERROR SEQUENCE 2. LOGGED ON: SID 13000202
DATE/TIME 8-JUL-1992 09:53:55.11 SYS_TYPE 04010002
SYSTEM UPTIME: 0 DAYS 00:00:14
SCS NODE: VAX/VMS T5.5-2X7
DEVICE ATTENTION KA49 CPU Microcode Rev # 2. CONSOLE FW REV# 0.1
Standard Microcode Patch Patch Rev # 1.
SCSI PORT SUB-SYSTEM, UNIT _PKA0:
ERROR TYPE 0005
PARITY ERROR DETECTED
SCSI ID 02
SCSI ID = 2.
SCSI CMD 12000000
0000
SCSI MSG 00
COMMAND COMPLETE
SCSI STATUS 00
GOOD
PORT ERROR CNT 00000000
00000000
00000000
BUS BUSY CNT = 0.
UNSOL RESET CNT = 0.
UNSOL INTRPT CNT = 0.
CONN ERROR CNT 00000000
00000000
00000000
00000000
00000000
Continued on next page
5–82