Technical data

Product Fault Management, Continued
logged by the host, and one or more device attention and other
assorted entries logged by the device drivers.
In these cases the processor module or one of the four memory
modules are the most likely cause of the errors. Therefore, it
is essential to analyze polled error entries, since a polled entry
usually represents the source of the error versus other entries,
which are aftereffects of the original error. This example provides
an abbreviated error log for a polled error.
V A X / V M S SYSTEM ERROR REPORT COMPILED 17-FEB-1992 05:32:21
PAGE 1.
************************** ENTRY 2. *******************************
ERROR SEQUENCE 15. LOGGED ON: SID 13000202
DATE/TIME 17-FEB-1992 05:22:00.90 SYS_TYPE 01430701
SYSTEM UPTIME: 0 DAYS 00:27:48
SCS NODE: VAX/VMS V5.5-1
POLLED ERROR KA49-A CPU FW REV# 2. CONSOLE FW REV# 4.3
REVISION 00000000
SYSTAT 00000001
ATTEMPTING RECOVERY
FLAGS 00000006
memory subpacket
KA49 subpacket
KA49 REGISTER SUBPACKET
BPCR ECC80024
.
.
.
MESR 8001B800
UNCORRECTABLE MEMORY ECC ERROR
ERROR SUMMARY
MEMORY ERROR SYNDROME = 1B(X)
.
.
.
MEAR 50000410
main memory error address =
00001040
ndal commander id = 05(X)
.
.
.
IPCR0 00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
MEMORY SUBPACKET
Continued on next page
5–81