Technical data
Product Fault Management, Continued
MEMORY CRD ENTRY 1.
FOOTPRINT 0000003D
MEMORY ERROR STATUS:
_SIMM MEMORY MODULE: LOCATION
0A
_set = 0.
Bank = B
VALID ENTRY CNT 00000001
1.
CURRENT ENTRY 00000001
1.
MEMORY CRD ENTRY 1.
FOOTPRINT 0000003D
MEMORY ERROR STATUS:
_SIMM MEMORY MODULE: LOCATION
0A
_set = 0.
ECC SYNDROME = 3D(X)
_CORRECTED DATA BIT = 3.
STATUS 00000059
PAGE MARKED BAD
HARD SINGLE ADDRESS
scrubbed
GENERATE REPORT
CRD CNT 00000002
2.
PAGE MAPOUT CNT 00000001
1.
FIRST EVENT 54886EE0
0095CECE
1-JUL-1992 13:55:10.67
LAST EVENT 5489F580
0095CECE
1-JUL-1992 13:55:10.68
LOWEST ADDRESS 00300000
HIGHEST ADDRESS 00300000
NOTE
Ownership (O-bit) memory correctable or fatal errors
(MESR <04> or MESR <03> of the processor Register
Subpacket set equal to 1 are processor module errors,
NOT memory errors.
Interpreting
DMA Host
Transaction
Faults Using
ANALYZE/ERROR
Some kernel errors may result in two or more entries being
logged. If the SHAC DSSI adapters or the SGEC Ethernet
controller or other CDAL device (residing on the processor
module) encounter host main memory uncorrectable ECC errors,
main memory NXMs or CDAL parity errors or timeouts, more
than one entry results. Usually there is one polled error entry
Continued on next page
5–80