Technical data

System Test Monitor, Continued
Examples:
The following is an example of a successful SCSI system test
message:
10 SCSI ################## 4
The following example shows an unsuccessful (error) SCSI system
test message. The error is on ID 5.
?? 10 SCSI 150 0076 8:18:41
The following is an example of the SCSI system test summary
message:
ADR RDS WRTS ERR FRU CMD PHS INF LBNSTRT XFERSIZ
--- --- ---- --- --- --- --- --- ------- -------
1/0 10987 0
3/0 5643 5643 36 1378 119
4/0 28 28 160 150 28 1
------------------------------------------------------------
4/0 XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX
Data is destroyed on hard disks in the manufacturing
environment, except for disks with factory installed software.
Data is not destroyed on hard disks in the Digital Services
environment.
All expansion boxes must have power supplied before the system
box is powered up, or the expansion box devices will not be
configured.
Common causes of errors or devices missing from the
configuration include:
SCSI Bus not terminated.
All device IDs are not unique.
Internal cables to the drives are disconnected.
The summary screen lists the test results by device ID.
When in the Digital Services environment, media must be present
in all removable media devices.
Continued on next page
5–41