Technical data
System Console Commands, Continued
Setting the
Diagnostic
Environment
To set the diagnostic environment, enter a console command listed
in Table 4–3. Note that all settings except DIAGENV 1 require a
loopback connector be installed.
Table 4–3 SET DIAGENV Command
Command Result
SET DIAGENV 1 Resets environment to customer mode.
SET DIAGENV 2 Sets environment to Digital Services
mode.
SET DIAGENV 3 Sets environment to manufacturing
mode.
SET DIAGENV
80000002
Sets environment to loop on error in
Digital Services mode.
SET DIAGENV
80000003
Sets environment to loop on error in
manufacturing mode.
Example:
>>> SET DIAGENV 2
DIAGENV = 2
>>> SHOW DIAGENV
DIAGENV = 2
Continued on next page