User`s guide

Chapter 4. EEROM Configuration Utility
EK–KZPBA–UG. B01 4–9
Figure 4–6 Edit EEROM Device Parameters Screen
+=====================Edit EEROM Device Parameters============== +
| |
| Parameters Default Dev0 Dev1 Dev2 Dev3 |
|Renegotiate on Error 1 [ 1 ] [ 1 ] [ ] [ 1 ] |
|Stop Queue on Check Condition 0 [ 0 ] [ 0 ] [ 0 ] [ 0 ] |
|Auto Request Sense 1 [ 1 ] [ 1 ] [ 1 ] [ 1 ] |
|Tagged Queuing 1 [ 0 ] [ 0 ] [ 0 ] [ 0 ] |
|Synchronous Data Transfers 1 [ 1 ] [ 1 ] [ 1 ] [ 1 ] |
|Wide Data Transfer 1 [ 1 ] [ 1 ] [ 1 ] [ 1 ] |
|Parity Checking 1 [ 1 ] [ 1 ] [ 1 ] [ 1 ] |
|Disconnect Allowed 1 [ 1 ] [ 1 ] [ 1 ] [ 1 ] |
|Execution Throttle 16 [16 ] [16 ] [16 ] [16 ] |
|Synchronous Period 12 [12 ] [12 ] [12 ] [12 ] |
|Synchronous Offset 8 [ 8 ] [ 8 ] [ 8 ] [ 8 ] |
|Device Enable 1 [ 1 ] [ 1 ] [ 1 ] [ 1 ] |
|--------------------------------------------------------------- |
| |
| < (O) K > < (C)ancel > |
| |
+=============================================================== +
2. Use the right and left arrow keys to move between devices. The device
columns scroll to the right for up to 15 devices.
3. Press
Enter
or use the up and down arrow keys to move through the list of
parameters. To change a parameter value, backspace over the value in the
New
field and type in a new value. If you enter a value out of the range for
this parameter, the utility will display an error message indicating the valid
range.
NOTE
For FAST-20 operation, the default for
synchronous period is 12 and the default for
synchronous offset is 8.
For FAST-10 operation, the default for
synchronous period is 25 and the default for
synchronous offset is 12.