User`s guide

Chapter 3. Installing the KZPBA–CA Adapter
EK–KZPBA–UG. B01 3–11
3.4.2 Host Adapter Termination
Termination on the KZPBA–CA single-ended host adapter module is software
controlled and its default is auto enabled. If you are using only one internal
connector or external connector, the default does not have to be changed.
Single-Ended Module
On the single-ended module, if you are using both internal connectors, the
default termination must be changed. To do this, first complete the installation,
then refer to the flash EEROM Configuration Utility (see Chapter 4).
3.4.3 Possible Termination Configurations
Internal Devices only
Internal devices can only be used with the KZPBA–CA Single-ended Host
Adapter. How you terminate the devices and the host adapter depends on
whether one or both of the module-edge connectors are used.
If only one of the board-edge connectors is used, you must terminate the last
internal device on the SCSI bus and disable termination on the other devices.
The host adapter is already terminated by default and this setting should not be
changed (see Figure 3–9).