User`s guide

Chapter 5. Second Controller Option
EK–SMCPO–UG. A01 5–5
9. Replace the existing controller into the top controller slot in the pedestal and
seat it into place by pushing forward on the side quick-disconnect handles.
Make sure the guides on each side of the controller align with the guides in
the slot.
10. Remove the dummy filler panel from the bottom controller slot by pulling
the handle straight out.
11. Install the second controller into the bottom controller slot and seat it into
place by pushing forward on the side quick-disconnect handles.
12. Power up the subsystem and refer to the RAID Array 3000 configuration and
maintenance guide (EK–SMCS2–UG) for information describing how to
configure the redundant controller option.