User`s guide

RAID Array 3000 Pedestal Enclosure
2–22 EK–SMCPO–UG. A01
WARNING
Slow Alarm
Normal I/O
SEVERE
UltraSCSI Alarm
Flushes Cache
Enters Write-Through Mode
OFFLINE
UltraSCSI Alarm
Flushes Cache
No New I/O Allowed
2.9.2 Voltage Monitoring
2.9.2.1 System Voltage
The controller monitors the incoming system voltage levels and ensures they are
satisfactory for controller operation. The acceptable voltage levels are listed in
Table 2–8.
Table 2–8 Acceptable System Voltage Levels
State Range Action
Normal 4.80 - 5.25 V Normal Operation
Low Warning 4.75 - 4.80 V Alarm
High Warning 5.25 - 5.30 V Alarm
Low Severe Less than 4.75 V Off-line
High Severe Greater than 5.30 V Off-line