User`s guide

RAID Array 3000 Storage Subsystem
1–6 EK–SMCPO–UG. A01
1.4 Pedestal Components
The major components in the pedestal subsystem include:
Dual-channel RAID array controller
Two 16-bit single-ended split SCSI buses
Environmental Monitor Unit (EMU)
Two universal 50/60 Hz, 120 or 240 Vac power supplies
Separate free-standing backup power supply (UPS)
1.4.1 StorageWorks Building Blocks (SBBs)
The pedestal has seven 3½-inch disk drive SBB slots. The number of drives that
make up each configuration of the array is left to the end user with a maximum
of seven storage devices.
1.4.2 RAID Array Controller
The controller contains two Wide/UltraSCSI/differential host channels and two
Wide/UltraSCSI/Single-Ended disk channels. In dual-controller configurations,
the controllers support fully automatic and smooth controller failover.
The controller supports one or two standard 72-pin cache SIMMs of up to
64 MB. In a redundant controller setup, both controllers must have identical
cache configurations and the total usable cache (per controller) will be half the
amount installed. Thus, in a single controller setup the maximum usable cache is
128 MB while a redundant setup has a maximum usable cache of 64 MB (per
controller).
The RAID Array controller contains the following features:
Single PCB form factor for inclusion in the enclosure
Support for dual hot-swap controller operation
Dual differential Ultra-Wide SCSI host channels
Dual single-ended Ultra-Wide SCSI disk channels
RAID level 0, 1, 0+1, 4, 5, and JBOD support
EMU support
Cluster support for Windows NT
32 Logical Units (LUNs) per host channel (some operating systems may be
limited to 8)
Support for Hot and Warm spare disks
UPS backed write caching