Installation guide
EK–SM3KC–IG. C01 1
Second Controller Option
This guide describes how to install a second RAID controller in the RAID Array 3000 pedestal
or controller shelf. The second controller option adds a fail/safe feature to your storage sub-
system.
NOTE
The following second controller option installation and
configuration procedure applies to both the desk-side
pedestal and the rack-mount controller shelf. For clar-
ity, only the pedestal is illustrated in this procedure.
1.0 Introduction
The controller option adds a second (redundant) controller unit to your subsystem to
preserve the integrity of data should the first controller malfunction. The second con-
troller is installed directly below the existing controller in the bottom controller slot
of the RAID Array 3000 pedestal (see Figure 1) or the rack-mount controller shelf
version of the subsystem.
The installation procedure consists of adding two SIMM memory modules to the re-
dundant controller and, depending on the option kit you are installing (see inventory
below), one or two SIMM modules to the existing controller. Following the memory
upgrade, you must upgrade the firmware in both controllers , seat the devices in their
respective controller slots and configure the subsystem to accommodate a redundant
controller.
Perform an inventory of the items contained in the second controller kit option. The
kit should contain the following:
RAID Array 3000 Controller
For option kit DS-HSZ22-AA, 3 SIMMs
For option kits DS-HSZ22-AB, 4 SIMMs
CD with new Firmware
Model Label
Warranty Card
This Guide